SERVICE / DETAILother

magent

GET api.magentlab.com/api/calc/canadian_cspine

SONAR SCORE0.000
LIVE PRICE0.005000
BAZAAR LIVEnot compatible
CDP INDEXEDno
DECISION EVIDENCE

Why an agent can trust this route.

1 observations in the last 24h
HANDSHAKE SUCCESS0.0%402 challenge reachable
PAID DELIVERY0.0%settlement observed
P90 LATENCY10023msrecent response window
PRICE DRIFTadvertised vs observed

Sonar evidence is advisory. Paid delivery is shown as verified only when paid probes are available; otherwise route estimates use the unpaid handshake as a clearly labeled proxy.

SONAR PROBE HISTORY / 30D

Observed outcomes

JSON ↗
LIVE ENDPOINT METADATA

Canadian C-spine rule (Stiell 2001). Cervical radiography is indicated if any high-risk factor is present (age ≥65, dangerous mechanism, or paresthesias in the extremities). If none, radiography is indicated unless at least one low-risk factor allows safe range-of-motion assessment and the patient can rotate the neck 45° left and right. Not a diagnosis, not NEXUS, and not pediatric. For alert, stable blunt-trauma adults with GCS 15. magent does not examine the neck.

Resource: api.magentlab.com/api/calc/canadian_cspine

Network: eip155:8453 · Asset: 0x833589fCD6eDb6E08f4c7C32D4f71b54bdA02913 · Pay to: 0x836Be278f1739fB4308091cD1852F7971Bc19Ee2

Payment methods: eip3009 · Last validation: 2026-09-14 10:59:03.432+00

{
  "input": {
    "type": "object",
    "required": [
      "type",
      "method"
    ],
    "properties": {
      "type": {
        "type": "string",
        "const": "http"
      },
      "method": {
        "enum": [
          "GET",
          "HEAD",
          "DELETE"
        ],
        "type": "string"
      },
      "headers": {
        "type": "object",
        "additionalProperties": {
          "type": "string"
        }
      },
      "queryParams": {
        "type": "object",
        "required": [
          "age",
          "dangerous_mechanism",
          "paresthesias_extremities",
          "simple_rear_end_mvc",
          "sitting_in_ed",
          "ambulatory_since_injury",
          "delayed_neck_pain",
          "midline_cspine_tenderness",
          "able_to_rotate_45"
        ],
        "properties": {
          "age": {
            "type": "integer",
            "description": "Age in years (18-120). Age ≥65 is a high-risk factor that mandates radiography; 64 does not."
          },
          "sitting_in_ed": {
            "type": "boolean",
            "description": "Sitting position in the emergency department. true or false as assigned by the caller. A low-risk factor that can allow safe range-of-motion assessment."
          },
          "able_to_rotate_45": {
            "type": "boolean",
            "description": "Able to actively rotate the neck 45 degrees left and right. true or false as assigned by the caller. Consulted only when there is no high-risk factor and at least one low-risk factor."
          },
          "delayed_neck_pain": {
            "type": "boolean",
            "description": "Delayed onset of neck pain. true or false as assigned by the caller. A low-risk factor that can allow safe range-of-motion assessment."
          },
          "dangerous_mechanism": {
            "type": "boolean",
            "description": "Dangerous mechanism as assigned by the caller. true or false. High-risk; when true, radiography is indicated without range-of-motion assessment."
          },
          "simple_rear_end_mvc": {
            "type": "boolean",
            "description": "Simple rear-end motor vehicle collision as assigned by the caller. true or false. A low-risk factor that can allow safe range-of-motion assessment."
          },
          "ambulatory_since_injury": {
            "type": "boolean",
            "description": "Ambulatory at any time since injury. true or false as assigned by the caller. A low-risk factor that can allow safe range-of-motion assessment."
          },
          "paresthesias_extremities": {
            "type": "boolean",
            "description": "Paresthesias in the extremities. true or false as assigned by the caller. High-risk; when true, radiography is indicated without range-of-motion assessment."
          },
          "midline_cspine_tenderness": {
            "type": "boolean",
            "description": "Midline cervical-spine tenderness. true or false as assigned by the caller. Absence of midline tenderness (false) is a low-risk factor that can allow safe range-of-motion assessment."
          }
        }
      }
    },
    "additionalProperties": false
  },
  "output": {
    "type": "object",
    "required": [
      "type"
    ],
    "properties": {
      "type": {
        "type": "string"
      },
      "example": {
        "type": "object"
      }
    }
  },
  "paymentRequirements": [
    {
      "raw": {
        "asset": "0x833589fCD6eDb6E08f4c7C32D4f71b54bdA02913",
        "extra": {
          "name": "USD Coin",
          "version": "2",
          "paymentFlow": "upfront",
          "resourceUrl": "https://api.magentlab.com/api/calc/canadian_cspine?able_to_rotate_45=true&age=40&ambulatory_since_injury=false&dangerous_mechanism=false&delayed_neck_pain=true&midline_cspine_tenderness=true&paresthesias_extremities=false&simple_rear_end_mvc=false&sitting_in_ed=false",
          "assetTransferMethod": "eip3009"
        },
        "payTo": "0x836Be278f1739fB4308091cD1852F7971Bc19Ee2",
        "amount": "5000",
        "scheme": "exact",
        "network": "eip155:8453",
        "maxTimeoutSeconds": 600
      },
      "asset": "0x833589fCD6eDb6E08f4c7C32D4f71b54bdA02913",
      "payTo": "0x836Be278f1739fB4308091cD1852F7971Bc19Ee2",
      "scheme": "exact",
      "network": "eip155:8453",
      "amountAtomic": "5000"
    },
    {
      "raw": {
        "asset": "0x833589fCD6eDb6E08f4c7C32D4f71b54bdA02913",
        "extra": {
          "name": "USD Coin",
          "version": "2",
          "withdrawDelay": 86400,
          "receiverAuthorizer": "0x3721824a31197dcDD2984cF43b92B6cc8A87c0Fb",
          "assetTransferMethod": "eip3009"
        },
        "payTo": "0x836Be278f1739fB4308091cD1852F7971Bc19Ee2",
        "amount": "5000",
        "scheme": "batch-settlement",
        "network": "eip155:8453",
        "maxTimeoutSeconds": 600
      },
      "asset": "0x833589fCD6eDb6E08f4c7C32D4f71b54bdA02913",
      "payTo": "0x836Be278f1739fB4308091cD1852F7971Bc19Ee2",
      "scheme": "batch-settlement",
      "network": "eip155:8453",
      "amountAtomic": "5000"
    }
  ]
}
METADATA PROVENANCE

Source catalog records are retained separately from live endpoint observations. Sonar score, uptime, and latency are advisory metrics. CDP indexing is not inferred from validation.